Intelligent Digital
Platform for Material Testing
Bring your material testing data
from spreadsheets and folders into one system.
| Sample No. | Sample | Method | Status | Specimen | Due |
|---|---|---|---|---|---|
| S26-1004-012 | Carbon/epoxy UD laminate | ASTM D3039 tension | Testing | 6 / 10 | 10-08 |
| S26-1004-011 | Aluminum alloy 6061-T6 bar | GB/T 228.1 room-temperature tension | Pending interpretation | 5 / 5 | 10-07 |
| S26-1003-087 | Polypropylene injection-moulded bars | ISO 178 flexure | Overdue 2 days | 10 / 10 | 10-02 |
| S26-1003-064 | Structural adhesive single-lap specimens | ASTM D1002 lap shear | Paused | 3 / 6 | 10-09 |
| S26-1002-230 | Glass/vinyl ester pultruded panel | ASTM D6641 compression | Report issued | 6 / 6 | 10-03 |
| S26-1002-198 | Carbon/epoxy quasi-isotropic laminate | ASTM D7137 compression after impact | Pending review | 5 / 5 | 10-06 |
| S26-1002-176 | Vulcanised rubber dumbbell specimens | ISO 37 tension | Pending specimen prep | 0 / 5 | 10-12 |
Solutions
Everything that used to live in separate places,
now in one system.
Work flows through one system
Requests, samples, tasks and progress move in one platform — data is entered once.
Learn moreAuto-archived
Raw data, curves and results are archived by sample and method; valid data flows into the material library.
Learn moreDirect acquisition & parsing
Test-machine data is acquired directly and result files are parsed automatically — less re-typing.
Learn moreReports generated directly
Reports are generated from test data; review and approval happen online.
Learn moreCentralised methods & standards
Standard revisions switch only after approval, updates are checked regularly, and every calculation records its algorithm version.
Learn moreFull traceability
Field-level audit trails keep old value, new value, operator and reason — immutable.
Learn moreReports delivered on time,
audits passed with confidence.
Day-to-day lab work revolves around these two things.
Report Generation
From request to report,
data is entered once.
Data is produced in the course of work, and reports are generated directly from test data. No re-transcription.
| Specimen | Width mm | Thickness mm | Tensile strength MPa | Modulus GPa |
|---|---|---|---|---|
| -01 | 25.02 | 2.104 | 2 188 | 141.2 |
| -02 | 25.06 | 2.098 | 2 097 | 139.8 |
| -03 | 24.98 | 2.110 | 2 156 | 140.5 |
| -04 | 25.01 | 2.101 | 2 203 | 142.0 |
| -05 | 25.03 | 2.107 | 2 121 | 140.9 |
| Specimen | Strength/MPa | Modulus/GPa |
|---|---|---|
| -01 | 2188 | 141.2 |
| -02 | 2097 | 139.8 |
| -03 | 2156 | 140.5 |
| -04 | 2203 | 142.0 |
| -05 | 2121 | 140.9 |
| Average | 2153 | 140.9 |
Electronic signatures
Auto-drafting
Reports are assembled automatically from test data and computed results.
Locked on confirmation
Data locks once confirmed; changes must record a reason and are kept on file.
Online verification
Two-level electronic signature; a verification code checks report status online.
Reports spanning dozens of pages,
every page laid out clearly.
Cover, contents, schematic, test conditions, result tables, curves, specimen photos, summary and signatures — assembled by module. Click any page to enlarge.
Assembled by module
Cover, contents, schematic, basic information, specimen preparation, test items, summary and signature pages — each switchable and reorderable.
Auto contents & pagination
Each test item starts its own page; contents page numbers and “Page n of N” update automatically.
Vector curves
Stress–strain, load–displacement and resistance curves are embedded as vector graphics — sharp when enlarged or printed.
Bilingual output
The same data produces a Chinese or English report, with headers, units and symbols switched as a set.
Statistical rows
Mean, standard deviation, coefficient of variation and characteristic values are generated with the result tables; the summary page compares across environments.
Specimen photos in place
Before, during and after test photos are filed by specimen number into the matching test item.
Revision history
Each revision increments the revision number; the revision history becomes its own page and earlier revisions stay traceable.
Seals & verification
Issued copies carry the dedicated seal and electronic signatures; a verification code checks report status online.
Compliance
Aligned with ISO/IEC 17025 accreditation,
with requirements built into every step.
Requirements of ISO/IEC 17025 are met as part of daily work. Audit evidence is always at hand — no last-minute assembly.
Resources & processes
The six factors that affect results,
controlled end to end.
Ensuring validity of results
Internal quality control,
external quality control,
run to plan.
QC categories and cycles are configured per method; the due list is the QC plan.
Internal QC
Personnel comparison, equipment comparison and retest are statistically judged in groups; control charts compute control limits point by point.
External QC
Proficiency testing and inter-laboratory comparison compute z and En values per parameter and issue an evaluation report.
Management system & data integrity
A management system that is documented,
and every change is traceable.
Document control
Controlled documents are marked with revision and status, revisions require approval, history is retained, and controlled reading is watermarked.
Record control
System records are archived by year and procedure; issue registers can be traced by revision.
Internal audit & management review
Audit plans, checklists and nonconformities are managed together; management review inputs are compiled automatically.
Nonconforming work & corrective actions
Quality events are managed in a closed loop, closed only after root-cause analysis and corrective actions are verified; complaints follow the same flow.
Risks & opportunities
The risk register rates likelihood and impact, and records responses and effectiveness.
Review & approval of results
Reports pass two levels of review — review and approval — with electronic signatures; revised reports issue as a new revision stating the reason.
Audit trail
Technical record changes keep old value, new value, operator, time and reason — immutable.
Access control & system validation
Role-based access control with re-verification at approval and issuance; system validation documents (IQ / OQ / PQ) ship with the installation.
AI
AI drafting,
rule-based interpretation, human confirmation.
Documents are read and filled by AI, curves are sampled automatically per the standard, and due items raise reminders. Every result takes effect only after human confirmation.
Rule-based
Interpretation per standard
24 calculation tools with interpretation rules written from the standard; sampling is traced and results are reproducible.
Rule-based
Two-level failure-mode judgement
First judge validity, then record the mode; invalid specimens are excluded from statistics.
AI drafting
Business intake
Reads the client and test items from the request form, fills the enquiry and drafts the quotation line items.
AI drafting
Equipment calibration
Reads calibration certificates and establishes metrological traceability item by item per the calibration plan.
AI drafting
Customer specifications
Breaks customer specifications into indicator items and matches each to a lab method.
AI drafting
Methods, price lists & supplier documents
Work instructions, price lists, supplier certificates and material data sheets are read, then checked and written in.
Material Data
Every test
becomes material data.
Data enters the same table through four paths, and valid data is grouped by material system. The more you measure, the more complete the library.
| Sample No. | Batch | Environment | Strength MPa |
|---|---|---|---|
| S26-1004-012 | B2609 | RTD | 2 153 |
| S26-0921-044 | B2608 | RTD | 2 176 |
| S26-0915-019 | B2608 | ETW | 1 968 |
| S26-0902-107 | B2607 | RTD | 2 131 |
Material library · Carbon/epoxy UD
Four data paths
Online entry, file parsing, direct instrument acquisition and batch upload.
Material library
Grouped by material system, giving mean, coefficient of variation and characteristic values.
Composites
Composite testing is
more than one sample, one test.
Composites start from a laminate — one panel, many specimens, multiple environments and batches.
Orvia adds dedicated data structures on top of the general flow.
Raw material batches
Fibre, resin and prepreg batch numbers are registered at source — results trace back to the batch.
Laminate
Layup, cure, thickness and void content are kept as structured specimen records.
One panel, many specimens
Specimens from one panel share provenance — each records its sampling position.
Environmental state
Room-temperature dry, cold dry and hot/wet groups form the full test matrix.
Dedicated interpretation
15 of the 24 calculation tools are composite-specific, covering 11 fracture-toughness tests.
Material card
Characteristic values per both GL 2010 and GL 2015.
Mobile
At the desk, beside the test machine.
Field work is done on the phone, on the spot. Scan to jump there — no back-at-the-desk re-entry.
Light & darkTwo appearances, consistent across desktop and mobile. Drag the divider to compare.
Deployment & integration
Deployed on your own lab’s servers.
On-premises deployment; the installer package is ready to use out of the box.
Deployment
- On-premises deployment
- Ships with default configuration
- Mobile updates in step with the web app
Integration
- Test-machine data acquisition and file parsing
- Reports and records export to PDF and Word
Access & security
- Role-based access control
- Approval and issuance re-verify the password
- Personnel privacy fields are encrypted
Lab branding
- The interface shows your lab’s own name and logo
- Reports carry your lab’s legal entity and seal
Pricing & licensing
A one-time licence,
an annual service fee.
On-premises deployment. The licence fee is set once, by lab size and the modules you select; version upgrades and technical support are charged as an annual service fee. The proposal is drawn up around your lab’s own situation.
Licence (one-time)
- Set by lab size and the modules you select
- Deployed on your own servers; data stays in the lab
- Added later as you take on new methods, people or machines
Service fee (annual)
- Version upgrades and technical support, charged by the year
- The scope of support is set out in the proposal
Implementation
- Installation, base data preparation, report layout configuration and staff training
- Scheduled around the scope your lab actually needs
Getting a quote
- Send us your lab size, the tests you run most and what you use today
- The proposal states the modules and mobile scope you license, the test machines and existing systems to be integrated, and what the licence fee and the service fee each come to
FAQ
The questions
that come up before go-live.
What happens to our spreadsheets and paper records?
At go-live we go through your current records type by type: base data such as customers, methods and equipment goes in first, then the requests and samples in progress move over project by project. The two run side by side during the transition, and the paper forms are retired once the system has settled in.
Can reports use our own layout and seal?
Yes. Reports carry your lab’s own legal entity, logo and seal. The sections and their order are configured once in the system, after which reports are assembled from the test data automatically. Reports are issued after two-stage review and approval with electronic signatures, and the verification code can be checked online.
Where is the data stored?
Entirely on your lab’s own servers — database, attachments and issued documents all stay local and never leave the lab. The mobile app reaches the same system over your lab’s network.
How do test machines connect?
Two ways: direct acquisition from the machine, or parsing the result file it exports. The exact models and output formats are confirmed machine by machine during the demo.
Do we maintain the test methods ourselves?
Yes. The method records are maintained by the lab: the standard, the work instruction, the raw-record template and the calculation rules all hang off the method. A standard revision is switched over after approval, and the system checks for updates on a schedule.
What can we do on a phone?
Scan samples into stock on receipt, photograph specimen preparation on the spot, scan equipment codes to check status, confirm flow nodes as they happen, upload attachments, work through approval to-dos, and report a quality event by holding to speak.
How long does go-live take?
Installation itself is a standard package; most of the time goes into preparing base data and configuring the report layout. After the demo we give you a staged implementation schedule based on your lab’s actual scope.
Say goodbye to spreadsheets and folders —
start with a real project.
With one real request from your lab, we will walk the whole process from sample receipt to report issuance.